Range 135 - 1.550 m³/h


Max. operating overpressure AC 205 - AC 250: 16 bar
AC 260 - AC 295: 10 bar
(16 bar optional)
Higher nominal output on request
   
PDP default setting (outlet) - 40° C
PDP optional -20° C / -70°C
Inlet temperature air 2° C / 50°C min./max.
Ambient temperature 5° C / 50°C min./max.
Electric power supply 100-240 VAC, 50-60 Hz;
24 VDC
Other voltages on request
   
Input filter 0,01 µm
Output filter 1,0 µm
Protection class IP 54
Extra-protection against splashes of water.
 
  Connection Volume flow Dimensions1 Weight2
    m³/h scfm A B C D E kg
AC 205 G1 135 79,5 1615 740 490 1585 680 150
AC 210 G1 155 91,2 1525 740 490 1490 680 190
AC 215 G1 200 117,7 1525 740 490 1490 680 190
AC 220 G1,5 280 164,8 1925 1030 620 1800 810 330
AC 225 G1,5 380 223,7 1925 1030 620 1800 810 330
AC 230 G1,5 500 294,3 1880 1030 620 1750 810 380
AC 240 G 2 630 370,8 1870 1220 750 1820 850 650
AC 250 G 2 800 470,9 1830 1220 830 1780 975 830
AC 260 G 2,5 1000 588,6 1725 1860 910 1200 1100 900
AC 275 G 2,5 1250 735,7 1725 1860 960 1200 1100 1060
AC 295 G 2,5 1550 912,3 1800 1860 1005 1230 1100 1260
 
1+/- 10 mm         2incl. Filter  
Performance date according to DIN ISO 7185 relate to an input pressure of 7 bar (overpressure) and an inlet temperature of 35°C. Please multiply with the corrective factors where the input conditions deviate.  
Corrective factors pressure / temperature  
bar 4 5 6 7 8 9 10 11 12 13 14 15 16
35°C 0,63 0,75 0,88 1,00 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,12
40°C 0,55 0,66 0,77 0,88 0,99 1,10 1,21 1,32 1,43 1,54 1,65 1,76 1,87
45°C 0,42 0,50 0,59 0,67 0,76 0,84 0,92 1,01 1,09 1,17 1,26 1,34 1,42
50°C 0,35 0,41 0,48 0,55 0,62 0,69 0,76 0,83 0,90 0,96 1,03 1,10 1,17