Technical Data |
Range 10 - 112 m³/h
|
|

|
| Max. operating
overpressure |
16 bar |
| |
| PDP default setting
(outlet) |
- 40° C
|
| |
| PDP
optional |
at 70% of nominal
capacity:
-70°C |
| |
| Inlet temperature
air |
2° C / 50°C
min./max. |
| |
| Ambient temperature |
5° C / 50°C
min./max. |
| |
| Electric power
supply |
100-240 VAC, 50-60
Hz;
12 - 24 VDC |
| Other voltages
on request |
| |
| Inlet filter |
0,01 µm , 0,01
mg/m³ |
| |
| integrated dust
filter |
1,0 µm |
| |
| |
|
|
|
| |
Connection |
Volume flow |
Dimensions |
Weight |
| |
|
m³/h |
scfm |
A |
B |
C |
D |
E |
kg |
| AC 119 |
G 3/8 |
10,2 |
6 |
504 |
281 |
92 |
- |
- |
14 |
| AC 122 |
G 3/8 |
13,6 |
8 |
565 |
281 |
92 |
- |
- |
15 |
| AC 126 |
G 3/8 |
17,0 |
10 |
635 |
281 |
92 |
- |
- |
16,5 |
| AC 136 |
G 3/8 |
25,5 |
15 |
815 |
281 |
92 |
- |
- |
19,5 |
| AC 148 |
G 3/8 |
37,4 |
22 |
1065 |
281 |
92 |
- |
- |
24 |
| AC 171 |
G 3/8 |
56,1 |
33 |
1460 |
281 |
92 |
- |
- |
31 |
| AC 191 |
G 1/2 |
74,8 |
44 |
1065 |
281 |
184 |
- |
- |
47 |
| AC 196 |
G 1/2 |
112,2 |
66 |
1460 |
281 |
184 |
- |
- |
61 |
|
|
Performance data in accordance with DIN
ISO 7185 relate to an input pressure of 7 bar (0) and an inlet temperature
of 35 °C. Please multiply by the appropriate corrective factors
where the input conditions deviate.
The regeneration air portion depends on the actual operating conditions.
At a system pressure of 7 bar, the average demand for regeneration
air amounts to approximately 15%. |
|
Corrective factors pressure / temperature |
|
| bar |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
| 35°C |
0,63 |
0,75 |
0,88 |
1,00 |
1,13 |
1,25 |
1,38 |
1,50 |
1,63 |
1,75 |
1,88 |
2,00 |
2,12 |
| 40°C |
0,55 |
0,66 |
0,77 |
0,88 |
0,99 |
1,10 |
1,21 |
1,32 |
1,43 |
1,54 |
1,65 |
1,76 |
1,87 |
| 45°C |
0,42 |
0,50 |
0,59 |
0,67 |
0,76 |
0,84 |
0,92 |
1,01 |
1,09 |
1,17 |
1,26 |
1,34 |
1,42 |
| 50°C |
0,35 |
0,41 |
0,48 |
0,55 |
0,62 |
0,69 |
0,76 |
0,83 |
0,90 |
0,96 |
1,03 |
1,10 |
1,17 |
|
|
|